Recherche documentaire industrielle

5 résultats pour « site:support.industry.siemens.com Openness HMI connection import XML Driver »

p.99

90885040_81318674_Programming_guideline_DOC_v15_en.pdf

Page 99Automatisme industriel
72%

ollowing entry: https://support.industry.siemens.com/cs/ww/en/view/109479728

Voir le contexte de la page
4 Hardware-Independent Programming 4.2 No bit memory but global data blocks  Programming Guideline for S7-1200/S7-1500 Entry ID: 81318674,    V1.5,    03/2017 99  Copyright  Siemens AG 2017 All rights reserved 4.2 No bit memory but global data blocks Advantages  Optimized global DBs are clearly more powerful than the bit memory address area that is not optimized only for reasons of compatibility. Recommendation  Dealing with bit memory (system and clock flags also) is problematic since the size of the flag area of each controller has is different. Do not use bit memory for the programming but always global data blocks. This is how the program can always be used universally.  4.3 Programming of "Cycle bits" Recommendation For the programming of clock memory, the hardware configuration always has to be correct. Use a programmed block as clock generator. Below, you can find a programming example for a clock generator in the SCL programming language. Example The programmed block has the following functions. A desired frequency is preset. The “Q” output is a Boolean value that toggles in the desired frequency. The “countdown” output outputs the remaining time of the current state of “q”. If the desired frequency is smaller or equal 0.0, then the output q = FALSE and Countdown = 0.0. Periodduration: 2 secondsFBfrequency [Real]q [Bool]countdown [Time]0.5T#0S_703MSTRUE  Note The complete programming example can be found in the following entry: https://support.industry.siemens.com/cs/ww/en/view/109479728
p.99

90885040_81318674_Programming_guideline_DOC_v15_en.pdf

Page 99Automatisme industriel
71%

ollowing entry: https://support.industry.siemens.com/cs/ww/en/view/109479728

Voir le contexte de la page
4 Hardware-Independent Programming 4.2 No bit memory but global data blocks  Programming Guideline for S7-1200/S7-1500 Entry ID: 81318674,    V1.5,    03/2017 99  Copyright  Siemens AG 2017 All rights reserved 4.2 No bit memory but global data blocks Advantages  Optimized global DBs are clearly more powerful than the bit memory address area that is not optimized only for reasons of compatibility. Recommendation  Dealing with bit memory (system and clock flags also) is problematic since the size of the flag area of each controller has is different. Do not use bit memory for the programming but always global data blocks. This is how the program can always be used universally.  4.3 Programming of "Cycle bits" Recommendation For the programming of clock memory, the hardware configuration always has to be correct. Use a programmed block as clock generator. Below, you can find a programming example for a clock generator in the SCL programming language. Example The programmed block has the following functions. A desired frequency is preset. The “Q” output is a Boolean value that toggles in the desired frequency. The “countdown” output outputs the remaining time of the current state of “q”. If the desired frequency is smaller or equal 0.0, then the output q = FALSE and Countdown = 0.0. Periodduration: 2 secondsFBfrequency [Real]q [Bool]countdown [Time]0.5T#0S_703MSTRUE  Note The complete programming example can be found in the following entry: https://support.industry.siemens.com/cs/ww/en/view/109479728
p.646

TIAPortalOpeness_frFR_fr-FR.pdf

Page 646Automatisme industriel
71%

ge></InstalledProducts></DocumentInfo><SW.Types.PlcStruct ID="0"><AttributeList><Interface><Sections xmlns="http://www.siemens.com/automation/Openness/SW/Interface/v5"><Section Name="None"><Member Name="Element_1" Datatype="Bool" /></Section></Sections></Interface><Name>UDT_1</Name><Namespace>Siemens</Namespace></AttributeList><ObjectList><MultilingualText ID="1" CompositionName="Comment"><ObjectList><MultilingualTextItem ID="2" CompositionName="Items"><AttributeList><Culture>en-US</Culture><Text /></AttributeList></MultilingualTextItem></ObjectList></MultilingualText><MultilingualText ID="3" CompositionName="Title">TIA Portal Openness API5.11 Fonctions permettant d'accéder aux données d'un automateOpenness : API pour l'automatisation de workflows d'ingénierie646Manuel système, 11/2023

Voir le contexte de la page
Attribut Namespace dans SIMATIC ML <?xml version="1.0" encoding="utf-8"?><Document><Engineering version="V18" /><DocumentInfo><Created>2022-08-03T05:28:40.722228Z</Created><ExportSetting>None</ExportSetting><InstalledProducts><Product><DisplayName>Totally Integrated Automation Portal</DisplayName><DisplayVersion>V18</DisplayVersion></Product><OptionPackage><DisplayName>TIA Portal Version Control Interface</DisplayName><DisplayVersion>V18</DisplayVersion></OptionPackage><Product><DisplayName>Feature Cycle 2 TIA Portal</DisplayName><DisplayVersion>V18</DisplayVersion></Product><Product><DisplayName>Feature Cycle 5 TIA Portal</DisplayName><DisplayVersion>V18</DisplayVersion></Product><Product><DisplayName>STEP 7 Professional</DisplayName><DisplayVersion>V18</DisplayVersion></Product><OptionPackage><DisplayName>STEP 7 Safety</DisplayName><DisplayVersion>V18</DisplayVersion></OptionPackage></InstalledProducts></DocumentInfo><SW.Types.PlcStruct ID="0"><AttributeList><Interface><Sections xmlns="http://www.siemens.com/automation/Openness/SW/Interface/v5"><Section Name="None"><Member Name="Element_1" Datatype="Bool" /></Section></Sections></Interface><Name>UDT_1</Name><Namespace>Siemens</Namespace></AttributeList><ObjectList><MultilingualText ID="1" CompositionName="Comment"><ObjectList><MultilingualTextItem ID="2" CompositionName="Items"><AttributeList><Culture>en-US</Culture><Text /></AttributeList></MultilingualTextItem></ObjectList></MultilingualText><MultilingualText ID="3" CompositionName="Title">TIA Portal Openness API5.11 Fonctions permettant d'accéder aux données d'un automateOpenness : API pour l'automatisation de workflows d'ingénierie646Manuel système, 11/2023
p.84

TIAPortalOpeness_frFR_fr-FR.pdf

Page 84Automatisme industriel
71%

<codeBase version="xx.x.x.x" href="FILE://C:\Program Files\Siemens\Automation\Portal Vxx\PublicAPI\Vxx\Siemens.Engineering.Hmi.dll"/> </dependentAssembly> </assemblyBinding> </runtime></configuration>TIA Portal Openness API5.2 Fonctions généralesOpenness : API pour l'automatisation de workflows d'ingénierie84Manuel système, 11/2023

Voir le contexte de la page
RemarqueNous vous recommandons de charger Siemens.Engineering.dll à l'aide du fichier de configuration d'application. Cette méthode permet de tenir compte des noms forts et les modifications dommageables au Engineering.dll entraînent une erreur de chargement. Ce qui n'est pas détectable en cas d'utilisation de la méthode AssemblyResolve. Démarrage de TIA Portal avec un fichier de configuration d'applicationCréez dans le fichier de configuration d'application des renvois à toutes les bibliothèques de programmes requises. Répartissez le fichier de configuration d'application avec l'application TIA Portal Openness. Enregistrez le fichier de configuration d'application "app.config" dans le même répertoire que l'application TIA Portal Openness et intégrez ce fichier dans votre application. Vérifiez dans chaque code si le chemin d'accès au fichier correspond au chemin d'installation de TIA Portal.Vous pouvez utiliser l'extrait de code suivant pour le fichier de configuration d'application :   <?xml version="1.0"?><configuration>    <runtime>        <assemblyBinding xmlns="urn:schemas-microsoft-com:asm.v1">            <dependentAssembly>                <assemblyIdentity name="Siemens.Engineering" culture="neutral" publicKeyToken="d29ec89bac048f84"/>                <!-- Edit the following path according to your installed version of TIA Portal -->                <codeBase version="xx.x.x.x" href="FILE://C:\Program Files\Siemens\Automation\Portal Vxx\PublicAPI\Vxx\Siemens.Engineering.dll"/>            </dependentAssembly>            <dependentAssembly>                <assemblyIdentity name="Siemens.Engineering.Hmi" culture="neutral" publicKeyToken="d29ec89bac048f84"/>                <!-- Edit the following path according to your installed version of TIA Portal -->                <codeBase version="xx.x.x.x" href="FILE://C:\Program Files\Siemens\Automation\Portal Vxx\PublicAPI\Vxx\Siemens.Engineering.Hmi.dll"/>            </dependentAssembly>        </assemblyBinding>    </runtime></configuration>TIA Portal Openness API5.2 Fonctions généralesOpenness : API pour l'automatisation de workflows d'ingénierie84Manuel système, 11/2023
p.73

TIAPortalOpeness_frFR_fr-FR.pdf

Page 73Automatisme industriel
71%

ns\Automation\Openness\xx.x\PublicAPI\xx.x.x.x]"PublicKeyToken"="d29ec89bac048f84""Siemens.Engineering"="C:\Program Files\Siemens\Automation\Portal Vxx\PublicAPI\Vxx\Siemens.Engineering.dll""Siemens.Engineering.Hmi"="C:\Program Files\Siemens\Automation\Portal Vxx\PublicAPI\Vxx\Siemens.Engineering.Hmi.dll""EngineeringVersion"="xx""AssemblyVersion"="xx.x.x.x"RemarqueSi vous souhaitez créer un fichier de configuration d'application (Page 83), vous pouvez connaître le chemin d'accès à Siemens.Engineering.dll, Siemens.Engineering.Hmi.dll et au jeton de la clé publique grâce à la clé de Registre. TIA Portal Openness API5.2 Fonctions généralesOpenness : API pour l'automatisation de workflows d'ingénierieManuel système, 11/202373

Voir le contexte de la page
UtilisationÀ partir de TIA Portal Openness V14, chaque version installée dispose d'une clé de Registre qui contient des informations sur la version. Cela permet de créer automatiquement le fichier de configuration d'application pour chaque version de TIA Portal Openness installée. La clé de Registre se trouve dans le chemin suivant :HKEY_LOCAL_MACHINE\Software\Siemens\Automation\Openness\xx.x\PublicAPIRemarqueLe numéro de version présent dans ce chemin est toujours identique au numéro de la version de TIA Portal actuelle installée. En cas de plusieurs installations parallèles, plusieurs jeux d'entrées correspondant à TIA Portal Openness sont présents dans le registre.Il existe une clé unique par version de TIA Portal Openness. Les noms des versions sont identiques à ceux dans l'Assembly décrit, par ex. les entrées de registre pour TIA Portal Openness :  [HKEY_LOCAL_MACHINE\SOFTWARE\Siemens\Automation\Openness\xx.x\PublicAPI\xx.x.x.x]"PublicKeyToken"="d29ec89bac048f84""Siemens.Engineering"="C:\Program Files\Siemens\Automation\Portal Vxx\PublicAPI\Vxx\Siemens.Engineering.dll""Siemens.Engineering.Hmi"="C:\Program Files\Siemens\Automation\Portal Vxx\PublicAPI\Vxx\Siemens.Engineering.Hmi.dll""EngineeringVersion"="xx""AssemblyVersion"="xx.x.x.x"RemarqueSi vous souhaitez créer un fichier de configuration d'application (Page 83), vous pouvez connaître le chemin d'accès à Siemens.Engineering.dll, Siemens.Engineering.Hmi.dll et au jeton de la clé publique grâce à la clé de Registre. TIA Portal Openness API5.2 Fonctions généralesOpenness : API pour l'automatisation de workflows d'ingénierieManuel système, 11/202373

Recherches populaires

Accédez à plus de résultats et fonctionnalités avancées.

Créer un compte gratuit